Research Article
Noise Parameter Analysis of SiGe HBTs for Different Sizes in the Breakdown Region
Table 2
Comparison between extracted and calculated breakdown noise spectral density at
V and
V for different sized SiGe HBTs.
| | from calculation (×10−22 A2 s) | from presented noise model (×10−22 A2 s) |