Research Article

A Research on Modification Method for NSM FRP-Concrete Bonded Joints Strength Models

Table 2

Database under the adhesive-concrete interface failure mode.

ReferenceTests numberMaterialfc (MPa)Ef (GPa)tp (mm)tf (mm) (mm)

[13]16CFRP/GFRP2237.17–174.178–11.38–11.310–24
[24]6CFRP34.5124121220–25
[29]13BFRP/GFRP/CFRP1946–1826–151.4–105–15
[30]28BFRP/GFRP/CFRP1942–1826–152.5–108–20
[31]11BFRP/GFRP/CFRP19.6–49.351–1776–151.4–85–15
[32]15CFRP34124–210121220
Total89BFRP/GFRP/CFRP19–49.337.17–2106–151.4–125–25