Research Article
A Research on Modification Method for NSM FRP-Concrete Bonded Joints Strength Models
Table 5
Database under the concrete crush or FRP rupture failure mode.
| Reference | Number of tests | FRP material | fc (MPa) | Ef (GPa) | tp (mm) | tf (mm) | (mm) |
| [33] | 4 | CFRP | 34.47–36.199 | 227.54 | 11 | 11 | 14 | [16] | 10 | GFRP | 33.4–53 | 161.8–162.3 | 10.1–20.47 | 1.24–1.28 | 3.24–3.28 | [29] | 4 | BFRP/CFRP | 19 | 46–177 | 6–10 | 1.4–6 | 10 | [30] | 4 | BFRP/CFRP | 19 | 46–177 | 6–10 | 1.4–6 | 5–10 | [37] | 8 | CFRP/GFRP | 41 | 43.5–128 | 9.5–12.7 | 9.5–12.7 | 14.25–25.4 | [6] | 4 | CFRP | 34–65.7 | 146 | 12 | 12 | 30 | [31] | 4 | CFRP/GFRP/BFRP | 29.7 | 48–180 | 8–10 | 8–10 | 13–15 | Total | 38 | CFRP/GFRP/BFRP | 19–65.7 | 43.5–227.54 | 6–20.47 | 1.24–12.7 | 3.24–30 |
|
|