Research Article

A Novel Flow-Perfusion Bioreactor Supports 3D Dynamic Cell Culture

Figure 3

Static cultured scaffolds had a 34% reduction in cellular viability at the periphery over the experimental period. In contrast, dynamic culture resulted in an 8.3% decrease in cell viability.
873816.fig.003