Research Article
The forensiX Evidence Collection Tube and Its Impact on DNA Preservation and Recovery
Table 5
Colony numbers on SDA plates.
| Sample type |
forensiX evidence collection tube stored at 25°C, 60% relative humidity over 14 days |
Sarstedt swab stored at 25°C, 60% relative humidity over 14 days |
| Swab no. | 1 | 2 | 3 | 4 | 5 | 6 | No dilution | <1 | <1 | <1 | 5 | >250 | >250 | 1 : 10 dilution | <1 | <1 | <1 | <1 | 39 | 19 | 1 : 100 dilution | <1 | <1 | <1 | <1 | 5 | <1 |
|
|