Research Article

A Vessel Active Contour Model for Vascular Segmentation

Table 3

Iterations, CPU time (in seconds), and MRMSE by the proposed model with both different manners of initial contours.

Image name/(row number of Figure 7)Initial contour used in Figure 7Initial contour set automatically
Iter. . (s)MRMSEIter. . (s)MRMSE

DSA_1/(1th)80029.7196.48322020.5166.122
DSA_2/(2th)135083.7187.93642018.7977.640
InfraredEyeVessel/(3th)55030.8754.3699016.8284.295
MRA_CerebralVessel/(4th)60024.93114.88913014.15114.653
MRA_CarotidVessel/(5th)100028.85611.74220019.62011.376
US_Plumonary/(6th)35060.1449.01011016.7728.855