BioMed Research International / 2014 / Article / Tab 3 / Clinical Study
Four-Dimensional Computed Tomography Based Respiratory-Gated Radiotherapy with Respiratory Guidance System: Analysis of Respiratory Signals and Dosimetric Comparison Table 3 Comparison of dose volume histogram (DVH) between plans with free breathing CT and 4D MIP CT.
(a) Liver Free breathing CT plan (cc) MIP based plan (cc) P value78.75 ± 3.51 68.06 ± 6.68 0.024 65.16 ± 7.83 54.24 ± 10.45 0.030 43.84 ± 12.80 35.22 ± 14.11 0.048 32.81 ± 12.68 27.34 ± 14.68 0.117 25.79 ± 11.47 21.53 ± 13.61 0.069 19.39 ± 9.71 16.06 ± 11.21 0.067
(b) Ipsilateral lung Free breathing CT plan MIP based plan P value48.97 ± 15.37 40.74 ± 11.07 0.051 37.71 ± 17.89 29.31 ± 15.22 0.035 23.02 ± 11.20 16.03 ± 8.75 0.018 15.19 ± 9.24 8.94 ± 5.46 0.034 9.18 ± 5.88 4.90 ± 3.18 0.035 1.64 ± 1.93 1.19 ± 1.35 0.287
(c) Contralateral lung Free breathing CT plan MIP based plan P value13.65 ± 12.29 8.91 ± 20.58 0.140 2.63 ± 4.90 1.01 ± 2.08 0.160 0 0
— 0 0 — 0 0 — 0 0 —
Volume receiving 5 Gy.† Volume receiving 10 Gy.‡ Volume receiving 20 Gy. Volume receiving 30 Gy. Volume receiving 40 Gy. Volume receiving 50 Gy.