Clinical Study

Four-Dimensional Computed Tomography Based Respiratory-Gated Radiotherapy with Respiratory Guidance System: Analysis of Respiratory Signals and Dosimetric Comparison

Table 3

Comparison of dose volume histogram (DVH) between plans with free breathing CT and 4D MIP CT.
(a) Liver

Free breathing CT plan (cc)MIP based plan (cc)P value

78.75 ± 3.5168.06 ± 6.680.024
65.16 ± 7.8354.24 ± 10.450.030
43.84 ± 12.8035.22 ± 14.110.048
32.81 ± 12.6827.34 ± 14.680.117
25.79 ± 11.4721.53 ± 13.610.069
19.39 ± 9.7116.06 ± 11.210.067

(b) Ipsilateral lung

Free breathing CT planMIP based planP value

48.97 ± 15.3740.74 ± 11.070.051
37.71 ± 17.8929.31 ± 15.220.035
23.02 ± 11.2016.03 ± 8.750.018
15.19 ± 9.248.94 ± 5.460.034
9.18 ± 5.884.90 ± 3.180.035
1.64 ± 1.931.19 ± 1.350.287

(c) Contralateral lung

Free breathing CT planMIP based planP value

13.65 ± 12.298.91 ± 20.580.140
2.63 ± 4.901.01 ± 2.080.160
00
00
00
00

Volume receiving 5 Gy.
Volume receiving 10 Gy.
Volume receiving 20 Gy.
Volume receiving 30 Gy.
Volume receiving 40 Gy.
Volume receiving 50 Gy.