Table of Contents Author Guidelines Submit a Manuscript
BioMed Research International
Volume 2014 (2014), Article ID 535929, 8 pages
http://dx.doi.org/10.1155/2014/535929
Research Article

An Ex Vivo Model in Human Femoral Heads for Histopathological Study and Resonance Frequency Analysis of Dental Implant Primary Stability

1Department of Traumatology and Orthopedic Surgery, “San Cecilio” Clinical Hospital, University of Granada, Spain
2Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, USA
3Oral Surgery and Implant Dentistry Department, School of Dentistry, University of Granada, Granada, Spain
4Department of Experimental Psychology, School of Psychology, University of Granada, Granada, Spain
5Department of Periodontics, School of Dentistry, University of Granada, Granada, Spain
6Department of Pathology, School of Medicine and Institute of Biopathology and Regenerative Medicine (IBIMER), University of Granada, Granada, Spain
7Departamento de Anatomía Patológica, Facultad de Medicina, 18012 Granada, Spain

Received 21 January 2014; Revised 12 May 2014; Accepted 19 May 2014; Published 4 June 2014

Academic Editor: Konstantinos Michalakis

Copyright © 2014 Pedro Hernández-Cortés et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. P. I. Branemark, R. Adell, U. Breine, B. O. Hansson, J. Lindstrom, and A. Ohlsson, “Intra-osseous anchorage of dental prostheses. I. Experimental studies,” Scandinavian Journal of Plastic and Reconstructive Surgery, vol. 3, no. 2, pp. 81–100, 1969. View at Google Scholar · View at Scopus
  2. T. Albrektsson, P.-I. Branemark, H.-A. Hansson, and J. Lindstrom, “Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man,” Acta Orthopaedica Scandinavica, vol. 52, no. 2, pp. 155–170, 1981. View at Google Scholar · View at Scopus
  3. C. E. Misch, J. Hoar, G. Beck, R. Hazen, and C. M. Misch, “A bone quality-based implant system: a preliminary report of stage I & stage II,” Implant Dentistry, vol. 7, no. 1, pp. 35–42, 1998. View at Google Scholar · View at Scopus
  4. R. Glauser, L. Sennerby, N. Meredith et al., “Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants,” Clinical Oral Implants Research, vol. 15, no. 4, pp. 428–434, 2004. View at Publisher · View at Google Scholar · View at Scopus
  5. H.-M. Huang, S.-Y. Lee, C.-Y. Yeh, and C.-T. Lin, “Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach,” Clinical Oral Implants Research, vol. 13, no. 1, pp. 65–74, 2002. View at Publisher · View at Google Scholar · View at Scopus
  6. M. C. Cehreli, A. M. Kokat, A. Comert, M. Akkocaoglu, I. Tekdemir, and K. Akca, “Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets,” Clinical Oral Implants Research, vol. 20, no. 10, pp. 1163–1169, 2009. View at Publisher · View at Google Scholar · View at Scopus
  7. L. Pagliani, L. Sennerby, A. Petersson, D. Verrocchi, S. Volpe, and P. Andersson, “The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study,” Journal of Oral Rehabilitation, vol. 40, no. 3, pp. 221–227, 2013. View at Publisher · View at Google Scholar · View at Scopus
  8. L. Sennerby and N. Meredith, “Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications,” Periodontology 2000, vol. 47, no. 1, pp. 51–66, 2008. View at Publisher · View at Google Scholar · View at Scopus
  9. N. Meredith, D. Alleyne, and P. Cawley, “Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis,” Clinical Oral Implants Research, vol. 7, no. 3, pp. 261–267, 1996. View at Google Scholar · View at Scopus
  10. H.-L. Chan, K. El-Kholy, J.-H. Fu, P. Galindo-Moreno, and H.-L. Wang, “Implant primary stability determined by resonance frequency analysis in surgically created defects: a pilot cadaver study,” Implant Dentistry, vol. 19, no. 6, pp. 509–519, 2010. View at Publisher · View at Google Scholar · View at Scopus
  11. P. Balleri, A. Cozzolino, L. Ghelli, G. Momicchioli, and A. Varriale, “Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study,” Clinical Implant Dentistry and Related Research, vol. 4, no. 3, pp. 128–132, 2002. View at Google Scholar · View at Scopus
  12. M. Atsumi, S.-H. Park, and H.-L. Wang, “Methods used to assess implant stability: current status,” The International Journal of Oral & Maxillofacial Implants, vol. 22, no. 5, pp. 743–754, 2007. View at Google Scholar · View at Scopus
  13. A. U. Guler, M. Sumer, I. Duran, E. O. Sandikci, and N. T. Telcioglu, “Resonance frequency analysis of 208 Straumann dental implants during the healing period,” Journal of Oral Implantology, vol. 39, no. 2, pp. 161–167, 2013. View at Publisher · View at Google Scholar · View at Scopus
  14. E. Nkenke, M. Hahn, M. Lell et al., “Anatomic site evaluation of the zygomatic bone for dental implant placement,” Clinical Oral Implants Research, vol. 14, no. 1, pp. 72–79, 2003. View at Publisher · View at Google Scholar · View at Scopus
  15. A. Monje, F. Monje, F. Suarez et al., “Comparison of implant primary stability between maxillary edentulous ridges receiving intramembranous origin block grafts,” Medicina Oral, Patologia Oral y Cirugia Bucal, vol. 18, no. 3, pp. e449–e454, 2013. View at Publisher · View at Google Scholar · View at Scopus
  16. A. Monje, I. Ortega-Oller, P. Galindo-Moreno et al., “Sensitivity of resonance frequency analysis for detecting early implant failure: a case-control study,” The International Journal Oral & Maxillofacial Implants, vol. 29, no. 2, pp. 456–461, 2014. View at Google Scholar
  17. M. I. Fanuscu, T.-L. Chang, and K. Akca, “Effect of surgical techniques on primary implant stability and peri-implant bone,” Journal of Oral and Maxillofacial Surgery, vol. 65, no. 12, pp. 2487–2491, 2007. View at Publisher · View at Google Scholar · View at Scopus
  18. I. Abrahamsson, E. Linder, and N. P. Lang, “Implant stability in relation to osseointegration: an experimental study in the Labrador dog,” Clinical Oral Implants Research, vol. 20, no. 3, pp. 313–318, 2009. View at Publisher · View at Google Scholar · View at Scopus
  19. E. Nkenke, M. Hahn, K. Weinzierl, M. Radespiel-Troger, F. W. Neukam, and K. Engelke, “Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants,” Clinical Oral Implants Research, vol. 14, no. 5, pp. 601–609, 2003. View at Publisher · View at Google Scholar · View at Scopus
  20. N. Meredith, D. Alleyne, and P. Cawley, “Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis,” Clinical Oral Implants Research, vol. 7, no. 3, pp. 261–267, 1996. View at Google Scholar · View at Scopus
  21. I. Turkyilmaz, “A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants,” Journal of Oral Rehabilitation, vol. 33, no. 10, pp. 754–759, 2006. View at Publisher · View at Google Scholar · View at Scopus
  22. I. Turkyilmaz, T. F. Tözüm, C. Tumer, and E. N. Ozbek, “Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement,” Journal of Oral Rehabilitation, vol. 33, no. 12, pp. 881–888, 2006. View at Publisher · View at Google Scholar · View at Scopus
  23. C. P. Sim and N. P. Lang, “Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length,” Clinical Oral Implants Research, vol. 21, no. 6, pp. 598–604, 2010. View at Publisher · View at Google Scholar · View at Scopus
  24. Y.-D. Song, S.-H. Jun, and J.-J. Kwon, “Correlation between bone quality evaluated by cone-beam computerized tomography and implant primary stability,” The International Journal of Oral & Maxillofacial Implants, vol. 24, no. 1, pp. 59–64, 2009. View at Google Scholar · View at Scopus
  25. V. Arisan, Z. C. Karabuda, H. Avsever, and T. Özdemir, “Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-assisted implant placement. Part I: relationship of radiographic gray density and implant stability,” Clinical Implant Dentistry and Related Research, vol. 15, no. 6, pp. 893–906, 2013. View at Publisher · View at Google Scholar
  26. I. Turkyilmaz, U. Aksoy, and E. A. McGlumphy, “Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data,” Clinical Implant Dentistry and Related Research, vol. 10, no. 4, pp. 231–237, 2008. View at Publisher · View at Google Scholar · View at Scopus
  27. A. Monje, F. Suarez, C. A. Garaicoa et al., “Effect of location on primary stability and healing of dental implants,” Implant Dentistry, vol. 23, no. 1, pp. 69–73, 2014. View at Publisher · View at Google Scholar
  28. I. Turkyilmaz, L. Sennerby, E. A. McGlumphy, and T. F. Tozum, “Biomechanical aspects of primary implant stability: a human cadaver study,” Clinical Implant Dentistry and Related Research, vol. 11, no. 2, pp. 113–119, 2009. View at Publisher · View at Google Scholar · View at Scopus
  29. K. Isoda, Y. Ayukawa, Y. Tsukiyama, M. Sogo, Y. Matsushita, and K. Koyano, “Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants,” Clinical Oral Implants Research, vol. 23, no. 7, pp. 832–836, 2012. View at Publisher · View at Google Scholar · View at Scopus
  30. L. Capek, A. Simunek, R. Slezak, and L. Dzan, “Influence of the orientation of the Osstell transducer during measurement of dental implant stability using resonance frequency analysis: a numerical approach,” Medical Engineering & Physics, vol. 31, no. 7, pp. 764–769, 2009. View at Publisher · View at Google Scholar · View at Scopus
  31. A. Nazarian, B. J. Hermannsson, J. Muller, D. Zurakowski, and B. D. Snyder, “Effects of tissue preservation on murine bone mechanical properties,” Journal of Biomechanics, vol. 42, no. 1, pp. 82–86, 2009. View at Publisher · View at Google Scholar · View at Scopus
  32. C. Ohman, E. Dall'Ara, M. Baleani, S. V. S. Jan, and M. Viceconti, “The effects of embalming using a 4% formalin solution on the compressive mechanical properties of human cortical bone,” Clinical Biomechanics, vol. 23, no. 10, pp. 1294–1298, 2008. View at Publisher · View at Google Scholar · View at Scopus
  33. K. Morita, K. Doi, H. Oue, S. Kajihara, K. Hayashi, and Y. Akagawa, “Influence of formalin fixation on the implant stability quotient and mechanical characteristics of bone,” British Journal of Oral and Maxillofacial Surgery, vol. 51, no. 6, pp. 550–554, 2013. View at Publisher · View at Google Scholar · View at Scopus
  34. H.-G. Yoon, S.-J. Heo, J.-Y. Koak, S.-K. Kim, and S.-Y. Lee, “Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value,” The Journal of Advanced Prosthodontics, vol. 3, no. 1, pp. 10–15, 2011. View at Publisher · View at Google Scholar · View at Scopus
  35. N. Farre-Pages, M. L. Auge-Castro, F. Alaejos-Algarra, J. Mareque-Bueno, E. Ferres-Padro, and F. Hernandez-Alfaro, “Relation between bone density and primary implant stability,” Medicina Oral, Patologia Oral y Cirugia Bucal, vol. 16, no. 1, Article ID 16799, pp. e62–e67, 2011. View at Publisher · View at Google Scholar · View at Scopus
  36. V. V. Kumar, K. Sagheb, M. O. Klein, B. Al-Nawas, P. H. Kann, and P. W. Kammerer, “Relation between bone quality values from ultrasound transmission velocity and implant stability parameters—an ex vivo study,” Clinical Oral Implants Research, vol. 23, no. 8, pp. 975–980, 2012. View at Publisher · View at Google Scholar · View at Scopus
  37. H. Martinez, M. Davarpanah, P. Missika, R. Celletti, and R. Lazzara, “Optimal implant stabilization in low density bone,” Clinical Oral Implants Research, vol. 12, no. 5, pp. 423–432, 2001. View at Google Scholar · View at Scopus
  38. M. Bischof, R. Nedir, S. Szmukler-Moncler, J.-P. Bernard, and J. Samson, “Implant stability measurement of delayed and immediately loaded implants during healing. A clinical resonance-frequency analysis study with sandblasted-and-etched ITI implants,” Clinical Oral Implants Research, vol. 15, no. 5, pp. 529–539, 2004. View at Publisher · View at Google Scholar · View at Scopus
  39. I. Miyamoto, Y. Tsuboi, E. Wada, H. Suwa, and T. Iizuka, “Influence of cortical bone thickness and implant length on implant stability at the time of surgery—clinical, prospective, biomechanical, and imaging study,” Bone, vol. 37, no. 6, pp. 776–780, 2005. View at Publisher · View at Google Scholar · View at Scopus
  40. G. Aad, B. Abbott, J. Abdallah et al., “Observation of a centrality-dependent dijet asymmetry in lead-lead collisions at sqrt[S(NN)] = 2.76 TeV with the ATLAS detector at the LHC,” Physical Review Letter, vol. 105, no. 25, Article ID 252303, 19 pages, 2010. View at Google Scholar
  41. B. L. Riggs, H. W. Wahner, W. L. Dunn, R. B. Mazess, K. P. Offord, and L. J. Melton III, “Differential changes in bone mineral density of the appendicular and axial skeleton with aging: relationship to spinal osteoporosis,” The Journal of Clinical Investigation, vol. 67, no. 2, pp. 328–335, 1981. View at Google Scholar · View at Scopus
  42. J. Roze, S. Babu, A. Saffarzadeh, M. Gayet-Delacroix, A. Hoornaert, and P. Layrolle, “Correlating implant stability to bone structure,” Clinical Oral Implants Research, vol. 20, no. 10, pp. 1140–1145, 2009. View at Publisher · View at Google Scholar · View at Scopus
  43. A. Cömert, A. M. Kokat, M. Akkocaglu, I. Tekdemir, K. Akça, and M. C. Çehreli, “Fresh-frozen vs. embalmed bone: is it possible to use formalin-fixed human bone for biomechanical experiments on implants?” Clinical Oral Implants Research, vol. 20, no. 5, pp. 521–525, 2009. View at Publisher · View at Google Scholar · View at Scopus
  44. G. Y. Rochefort, S. Pallu, and C. L. Benhamou, “Osteocyte: the unrecognized side of bone tissue,” Osteoporosis International, vol. 21, no. 9, pp. 1457–1469, 2010. View at Publisher · View at Google Scholar · View at Scopus