Author |
Year | Number of patients |
Symptomatic |
Asymptomatic |
Histology |
Contrast agent |
Ultrasound apparatus |
Vascular probe |
Mechanical index | CEUS analysis | Results | Semiautomated analysis | Visual assessment | CEUS and histology | CEUS and carotid symptoms | CEUS and echogenicity | CEUS and other vulnerable characteristics | CEUS and gender | Software and visual assessment |
|
Li et al. [9] | 2014 | 17 | 13 | 4 | 1 | SonoVue | Philips iU-22 ultrasound system | L 9-3 | 0,07 | 1 | 1 | 0,002 | 0 | 0 | 0 | 0 | 0 |
| Hjelmgren et al. [10] | 2014 | 13 | 7 | 6 | 0 | SonoVue | Siemens S2000 system | L 9-4 | 0,06 | 1 | 1 | 0 | 0,05 | 0,01 | 0 | 0 | 0,001 |
| Kim et al. [11] | 2014 | 89 | 0 | 89 | 1 | SonoVue | Acuson Sequoia 512 Siemens system | L 15-8 | 0,19 | 0 | 1 | 0,021 | 0 | 0 | 0 | 0 | 0 |
| van den Oord et al. [12] | 2014 | 143 | 0 | 143 | 0 | SonoVue | Philips iU-22 ultrasound system | L 9-3 | 0,06–0,08 | 1 | 1 | 0 | 0 | 0 | 0 | 0,03 | 0 |
|
Müller et al. [13] | 2014 | 33 | 17 | 16 | 1 | SonoVue | Antares Siemens system | nn | nn | 1 | 1 | 0,01 | Not significant | 0 | 0 | 0 | 0,02 |
| Vavuranakis et al. [14] | 2013 | 14 | 0 | 14 | 1 | SonoVue | Acuson Sequoia 512 Siemens system | L 15-8 | nn | 1 | 0 | 0,002 | 0 | 0 | 0 | 0 | 0 |
| Ritter et al. [15] | 2013 | 41 | 41 | 0 | 0 | SonoVue | GE Logiq 7 system | L 9-3 | nn | 0 | 1 | 0 | 0 | 0 | 0,02 | 0 | 0 |
| Hjelmgren et al. [16] | 2013 | 52 | 10 | 42 | 0 | SonoVue | Siemens S2000 system | L 9-4 | 0,06 | 1 | 0 | 0 | Not significant | 0,02 | 0 | 0 | 0 |
| van den Oord et al. [17] | 2013 | 69 | 0 | 69 | 0 | SonoVue | Philips iU-22 ultrasound system | L 9-3 | 0,06–0,08 | 1 | 1 | 0 | 0 | 0 | 0,05 | 0 | 0 |
| Zhou et al. [18] | 2013 | 46 | 24 | 22 | 0 | SonoVue | Acuson Sequoia 512 Siemens system | L 2 | 0,07 | 0 | 1 | 0 | Not significant | 0 | 0,05 | 0 | 0 |
| Varetto et al. [19] | 2012 | 51 | 12 | 39 | 1 | SonoVue | Esaote MyLab 25 Gold system | L 9-2 | nn | 1 | 0 | 0,001 | 0,01 | 0,02 | 0 | 0 | 0 |
| Faggioli et al. [20] | 2011 | 22 | 7 | 15 | 1 | SonoVue | Philips iU-22 ultrasound system | L 9-3 | 0.13 | 1 | 0 | 0,003 | 0,006 | 0 | 0 | 0 | 0 |
| Hoogi et al. [21] | 2011 | 27 | 8 | 19 | 1 | Definity | Philips iU-22 ultrasound system | L 8-4 | | 1 | 0 | 0,01 | 0 | 0 | 0 | 0 | 0 |
| Shalhoub et al. [22] | 2011 | 31 | 16 | 15 | 1 | SonoVue | Philips iU-22 ultrasound system | L 12-5 | 0,34 | 1 | 0 | 0,004 | 0 | 0 | 0 | 0 | 0 |
| Owen et al. [23] | 2010 | 37 | 16 | 21 | 0 | SonoVue | Philips iU-22 ultrasound system | L 12-5 | 0,34 | 1 | 0 | 0 | 0,005 | 0 | 0 | 0 | 0 |
| Huang et al. [24] | 2010 | 183 | 86 | 97 | 0 | SonoVue | Acuson Sequoia 512 Siemens system | L 15-8 | 0,35 | 1 | 1 | 0 | 0,001 | 0 | 0 | 0 | 0,001 |
| Staub et al. [25] | 2010 | 147 | 17 | 130 | 0 | Definity | ATL HDI 5000 Philips system | L 7-4 | 0,06–0,1 | 0 | 1 | 0 | 0 | 0 | 0,034 | 0 | 0 |
| Giannoni et al. [26] | 2009 | 77 | 64 | 9 | 1 | SonoVue | Acuson Sequoia 512 Siemens system | L 9-3 | 0,4–1,4 | 1 | 1 | >0,05 | 0,001 | 0,001 | 0 | 0 | 0 |
| Magnoni et al. [27] | 2009 | 25 | 0 | 25 | 0 | Optison | GE Vivid 7 system | L 7 | 0,08–01 | 0 | 1 | 0 | 0 | 0 | 0,001 | 0 | 0 |
| Xiong et al. [28] | 2009 | 104 | 35 | 69 | 0 | SonoVue | GE Logiq 9 system | L 9-3 | 0,13 | 1 | 0 | 0 | 0,001 | 0 | 0 | 0 | 0 |
| Huang et al. [29] | 2008 | 63 | 0 | 63 | 0 | SonoVue | Acuson Sequoia 512 Siemens system | L 15-8 | 0,35 | 1 | 0 | 0 | 0 | 0,01 | 0 | 0 | 0 |
| Coli et al. [30] | 2008 | 32 | 28 | 4 | 1 | Optison | GE Vivid 7 system | L 7 | 0,08–0,1 | 0 | 1 | 0,005 | | 0,001 | 0 | 0 | 0 |
|
Vicenzini et al. [31] | 2007 | 23 | 0 | 23 | 1 | SonoVue | Acuson Sequoia 512 Siemens system | L 6-15 | 0,4–1,4 | 0 | 1 | >0,05 | 0 | >0,05 | >0,05 | 0 | 0 |
| Shah et al. [32] | 2007 | 17 | 5 | 12 | 1 | Optison | ATL HDI 5000 Philips system | L 7-4 | 0,06–0,1 | 0 | 1 | 0,002 | 0 | 0 | 0 | 0 | 0 |
| Total | | 1356 | 406 | 946 | 12 | | | | | 16 | 15 | | | | | | |
|
|