Table of Contents Author Guidelines Submit a Manuscript
BioMed Research International
Volume 2015, Article ID 294197, 9 pages
http://dx.doi.org/10.1155/2015/294197
Research Article

Understanding the Correlation between Tomographic and Biomechanical Severity of Keratoconic Corneas

1Cornea and Refractive Surgery, Narayana Nethralaya, Bangalore 560010, India
2Cornea Clinic, Department of Ophthalmology, Maastricht University Medical Center, 6211 LK Maastricht, The Netherlands
3Imaging, Biomechanics and Mathematical Modeling Solutions, Narayana Nethralaya, Bangalore 560099, India

Received 31 May 2014; Revised 14 October 2014; Accepted 15 October 2014

Academic Editor: George Asimellis

Copyright © 2015 Rohit Shetty et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. C. J. Roberts and W. J. Dupps Jr., “Biomechanics of corneal ectasia and biomechanical treatments,” Journal of Cataract & Refractive Surgery, vol. 40, no. 6, pp. 991–998, 2014. View at Publisher · View at Google Scholar · View at Scopus
  2. G. Wollensak, E. Spoerl, and T. Seiler, “Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus,” American Journal of Ophthalmology, vol. 135, no. 5, pp. 620–627, 2003. View at Publisher · View at Google Scholar · View at Scopus
  3. S. A. Greenstein, K. L. Fry, and P. S. Hersh, “Corneal topography indices after corneal collagen crosslinking for keratoconus and corneal ectasia: one-year results,” Journal of Cataract and Refractive Surgery, vol. 37, no. 7, pp. 1282–1290, 2011. View at Publisher · View at Google Scholar · View at Scopus
  4. S. A. Greenstein, K. L. Fry, M. J. Hersh, and P. S. Hersh, “Higher-order aberrations after corneal collagen crosslinking for keratoconus and corneal ectasia,” Journal of Cataract & Refractive Surgery, vol. 38, no. 2, pp. 292–302, 2012. View at Publisher · View at Google Scholar · View at Scopus
  5. G. D. Kymionis, M. A. Grentzelos, D. M. Portaliou et al., “Photorefractive keratectomy followed by same-day corneal collagen crosslinking after intrastromal corneal ring segment implantation for pellucid marginal degeneration,” Journal of Cataract & Refractive Surgery, vol. 36, no. 10, pp. 1783–1785, 2010. View at Publisher · View at Google Scholar · View at Scopus
  6. P. Padmanabhan, A. Radhakrishnan, A. Venkataraman, N. Gupta, and B. Srinivasan, “Corneal changes following collagen cross linking and simultaneous topography guided photoablation with collagen cross linking for keratoconus,” Indian Journal of Ophthalmology, vol. 62, no. 2, pp. 229–235, 2014. View at Publisher · View at Google Scholar · View at Scopus
  7. R. Arora, P. Jain, J. L. Goyal, and D. Gupta, “Comparative analysis of refractive and topographic changes in early and advanced keratoconic eyes undergoing corneal collagen crosslinking,” Cornea, vol. 32, no. 10, pp. 1359–1364, 2013. View at Publisher · View at Google Scholar · View at Scopus
  8. D. P. Piñero, J. L. Alio, R. I. Barraquer, R. Michael, and R. Jiménez, “Corneal biomechanics, refraction, and corneal aberrometry in keratoconus: an integrated study,” Investigative Ophthalmology and Visual Science, vol. 51, no. 4, pp. 1948–1955, 2010. View at Publisher · View at Google Scholar · View at Scopus
  9. S. Tejwani, R. Shetty, M. Kurien, S. Dinakara, A. Ghosh, and A. S. Roy, “Biomechanics of the cornea evaluated by spectral analysis of waveforms from ocular response analyzer and Corvis-ST,” Plos ONE, vol. 9, no. 8, Article ID e97591, 2014. View at Publisher · View at Google Scholar
  10. M. Abou Shousha, V. L. Perez, A. P. F. S. Canto et al., “The use of Bowman's layer vertical topographic thickness map in the diagnosis of keratoconus,” Ophthalmology, vol. 121, no. 5, pp. 988–993, 2014. View at Publisher · View at Google Scholar · View at Scopus
  11. G. H. Bae, J. R. Kim, C. H. Kim, D. H. Lim, E. S. Chung, and T.-Y. Chung, “Corneal topographic and tomographic analysis of fellow eyes in unilateral keratoconus patients using pentacam,” American Journal of Ophthalmology, vol. 157, no. 1, pp. 103.e1–109.e1, 2014. View at Publisher · View at Google Scholar · View at Scopus
  12. J. Steinberg, M. Ahmadiyar, A. Rost et al., “Anterior and posterior corneal changes after crosslinking for keratoconus,” Optometry and Vision Science, vol. 91, no. 2, pp. 178–186, 2014. View at Publisher · View at Google Scholar · View at Scopus
  13. A. M. Mahmoud, M. X. Nuñez, C. Blanco et al., “Expanding the cone location and magnitude index to include corneal thickness and posterior surface information for the detection of keratoconus,” The American Journal of Ophthalmology, vol. 156, no. 6, pp. 1102–1111, 2013. View at Publisher · View at Google Scholar · View at Scopus
  14. A. J. Kanellopoulos and G. Asimellis, “Revisiting keratoconus diagnosis and progression classification based on evaluation of corneal asymmetry indices, derived from scheimpflug imaging in keratoconic and suspect cases,” Clinical Ophthalmology, vol. 7, pp. 1539–1548, 2013. View at Publisher · View at Google Scholar · View at Scopus
  15. R. H. Silverman, R. Urs, A. Roychoudhury, T. J. Archer, M. Gobbe, and D. Z. Reinstein, “Epithelial remodeling as basis for machine-based identification of keratoconus,” Investigative Ophthalmology & Visual Science, vol. 55, no. 3, pp. 1580–1587, 2014. View at Publisher · View at Google Scholar · View at Scopus
  16. A. J. Kanellopoulos, V. Moustou, and G. Asimellis, “Evaluation of visual acuity, pachymetry and anterior-surface irregularity in keratoconus and crosslinking intervention follow-up in 737 cases,” International Journal of Keratoconus and Ectatic Corneal Diseases, vol. 2, no. 3, pp. 95–103, 2013. View at Google Scholar
  17. B. M. Fontes, R. Ambrósio Jr., M. Salomão, G. C. Velarde, and W. Nosé, “Biomechanical and tomographic analysis of unilateral keratoconus,” Journal of Refractive Surgery, vol. 26, no. 9, pp. 677–681, 2010. View at Publisher · View at Google Scholar · View at Scopus
  18. E. Spoerl, N. Terai, F. Scholz, F. Raiskup, and L. E. Pillunat, “Detection of biomechanical changes after corneal cross-linking using ocular response analyzer software,” Journal of Refractive Surgery, vol. 27, no. 6, pp. 452–457, 2011. View at Publisher · View at Google Scholar · View at Scopus
  19. M. Mikielewicz, K. Kotliar, R. I. Barraquer, and R. Michael, “Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus,” British Journal of Ophthalmology, vol. 95, no. 6, pp. 793–798, 2011. View at Publisher · View at Google Scholar · View at Scopus
  20. A. Luz, B. M. Fontes, B. Lopes, I. Ramos, P. Schor, and R. Ambrósio, “Ora waveform-derived biomechanical parameters to distinguish normal from keratoconic eyes,” Arquivos Brasileiros de Oftalmologia, vol. 76, no. 2, pp. 111–117, 2013. View at Publisher · View at Google Scholar · View at Scopus
  21. B. V. Ventura, A. P. Machado, R. Ambrósio Jr. et al., “Analysis of waveform-derived ora parameters in early forms of keratoconus and normal corneas,” Journal of Refractive Surgery, vol. 29, no. 9, pp. 637–643, 2013. View at Publisher · View at Google Scholar · View at Scopus
  22. K. M. Hallahan, A. Sinha Roy, R. Ambrosio Jr., M. Salomao, and W. J. Dupps Jr., “Discriminant value of custom ocular response analyzer waveform derivatives in keratoconus,” Ophthalmology, vol. 121, no. 2, pp. 459–468, 2014. View at Publisher · View at Google Scholar · View at Scopus
  23. T. Dada, V. Konkal, R. Tandon, R. Singh, and R. Sihota, “Corneal topographic response to intraocular pressure reduction in patients with vernal keratoconjunctivitis and steroid-induced glaucoma,” Eye, vol. 21, no. 2, pp. 158–163, 2007. View at Publisher · View at Google Scholar · View at Scopus
  24. N. M. Sergienko and I. V. Shargorodska, “Corneal biomechanical property measurement with an IOP loading method in keratoconic patients,” Current Eye Research, vol. 39, no. 10, pp. 994–999, 2014. View at Publisher · View at Google Scholar
  25. N. Q. Ali, D. V. Patel, and C. N. McGhee, “Biomechanical responses of healthy and keratoconic corneas measured using a noncontact scheimpflug-based tonometer,” Investigative Ophthalmology & Visual Science, vol. 55, no. 6, pp. 3651–3659, 2014. View at Publisher · View at Google Scholar
  26. S. Kling, N. Bekesi, C. Dorronsoro, D. Pascual, and S. Marcos, “Corneal viscoelastic properties from finite-element analysis of in vivo air-puff deformation,” PLoS ONE, vol. 9, no. 8, Article ID e104904, 2014. View at Publisher · View at Google Scholar
  27. A. Sinha Roy and R. S. Shetty, “Estimated corneal elastic moduli from inverse finite element analysis of corneal deformation in vivo,” ARVO Meeting Abstracts, vol. 55, p. 3701, 2014. View at Google Scholar
  28. A. S. Roy, K. M. Rocha, J. B. Randleman, R. D. Stulting, and W. J. Dupps Jr., “Inverse computational analysis of in vivo corneal elastic modulus change after collagen crosslinking for keratoconus,” Experimental Eye Research, vol. 113, pp. 92–104, 2013. View at Publisher · View at Google Scholar · View at Scopus
  29. M. Winkler, G. Shoa, Y. Xie et al., “Three-dimensional distribution of transverse collagen fibers in the anterior human corneal stroma,” Investigative Ophthalmology and Visual Science, vol. 54, no. 12, pp. 7293–7301, 2013. View at Publisher · View at Google Scholar · View at Scopus
  30. G. Scarcelli, S. Kling, E. Quijano, R. Pineda, S. Marcos, and S. H. Yun, “Brillouin microscopy of collagen crosslinking: noncontact depth-dependent analysis of corneal elastic modulus,” Investigative Ophthalmology and Visual Science, vol. 54, no. 2, pp. 1418–1425, 2013. View at Publisher · View at Google Scholar · View at Scopus
  31. M. R. Ford, A. S. Roy, A. M. Rollins, and W. J. Dupps Jr., “Serial biomechanical comparison of edematous, normal, and collagen crosslinked human donor corneas using optical coherence elastography,” Journal of Cataract and Refractive Surgery, vol. 40, no. 6, pp. 1041–1047, 2014. View at Publisher · View at Google Scholar · View at Scopus
  32. D. Touboul, J.-L. Gennisson, T.-M. Nguyen et al., “Supersonic shear wave elastography for the in vivo evaluation of transepithelial corneal collagen cross- linking,” Investigative Ophthalmology and Visual Science, vol. 55, no. 3, pp. 1976–1984, 2014. View at Publisher · View at Google Scholar · View at Scopus
  33. J. Lenk, M. Haustein, E. Spoerl, and L. E. Pillunat, “Characterization of corneal biomechanical response parameters in pellucid marginal dystrophy, keratoconus and normal corneas,” in Proceedings of the ARVO Meeting Abstracts, 2014.