Research Article

An Electromechanical Left Ventricular Wedge Model to Study the Effects of Deformation on Repolarization during Heart Failure

Table 4

Minimum (min), maximum (max), and dispersion (disp) of ACT, REP, and APD computed from the simulations with and without considering deformation.

ā€‰ Without deformation With deformation
ā€‰ min max disp min max disp

ACT (ms) 2.5 31.6 29.1 2.6 33.4 30.8
REP (ms) 309.3 322.8 13.5 303.5 327.7 24.2
APD (ms) 281.1 309.1 28.0 277.9 311.9 34.0