Research Article
A Data Hiding Technique to Synchronously Embed Physiological Signals in H.264/AVC Encoded Video for Medicine Healthcare
Table 4
Experimental results for seven video test sequences.
| Video sequences | Embedded capacity (bits) | Modified MBs | Modified QP-MV | PSN (dB) | BRI (%) | Oe (%) |
| Football | 45598 | 0 | 6957 | 0.011 | 0.4459 | −0.3787 | Mobile | 43598 | 0 | 7017 | −0.002 | 0.5837 | −0.1273 | Foreman | 28550 | 0 | 6702 | 0 | 0.9341 | −2.6196 | Carphone | 23454 | 0 | 6699 | −0.007 | 1.3446 | −2.2459 | Neonatal | 16544 | 944 | 6364 | 0.029 | 5.604 | −1.1826 | Akiyo | 5718 | 6357 | 5145 | −0.003 | 33.3143 | 15.8725 | Bridge-far | 3650 | 7391 | 4662 | −0.002 | 36.575 | 19.3017 |
|
|