Automatic Epileptic Seizure Detection Using Scalp EEG and Advanced Artificial Intelligence Techniques
Table 10
Classifier performance results for top 20 uncorrelated features using SMOTE.
Classifier
Sensitivity
Specificity
AUC
LDC
72%
84%
54%
QDC
64%
94%
64%
UDC
38%
95%
66%
POLYC
72%
84%
85%
LOGLC
82%
88%
92%
KNNC
90%
91%
96%
TREEC
87%
88%
92%
PARZENC
75%
92%
57%
SVC
82%
89%
91%