Research Article

Biomechanical Consequences of the Elastic Properties of Dental Implant Alloys on the Supporting Bone: Finite Element Analysis

Table 2

Maximum and minimum von Mises stresses (MPa) in cortical and trabecular bones and implants for all fabrication materials.

Fabrication material ā€‰von Mises stress (MPa)
CorticalTrabecularImplant

Y-TZPMin0.14340.038510.953
Max16.2062.142113.22
Ti-6Al-4VMin0.142380.037790.748
Max16.9452.03891.23
Ti-Nb-ZrMin0.14160.037160.638
Max17.2711.94876.673