Viscosity and osmolality of the 3 generations of radiocontrast materials (RCM). The iodine/molecule ratio is 1.5 : 1 in high-osmolality contrast media (HOCM), 3 : 1 in LOCM (tri-iodinated molecules), and 6 : 1 in IOCM dimers [61].

Osmol. group NameChem structViscosity (mPa)Osmolality (m)Year intro.
(intro.)ChemicalBrand(20°C)(37°C)mOsm/kg H2O

Isoosmotic (IOCM) (1990s)IodixanolVisipaqueNonionic dimer26.611.12901996
IotrolanIovist6.89.53201989
Low (LOCM) (1980s)IoxaglateHexabrixIonic dimer15.77.56001985
IoxilanOxilanNonionic monomer16.37.86951995
IomeprolImeron15.68.17261994
IopromideUltravist229.57701995
IohexolOmnipaque20.411.27801985
IoversolOptiray188.57921988
IopamidolIsovue20.99.87961997
IobitridolXenetix21109151994
High (HOCM) (1950s)DiatrizoateCrystographin HypaqueIonic monomer18.58.42000, 15501955
MetrizoateIsopaqueNA3.421001959
IothalamateConrayNA924001962