Research Article

Impact of Orthodontic Brackets on the Intraoral Scan Data Accuracy

Table 1

Arch width digital measurements on 3D scan model images (unit: mm).

 E4D DentistiTero
 Model BModel LSignificantModel BModel LSignificant

Maxillary intermolar width53.4953.872.06NS54.7554.760.62NS
Mandibular intermolar width48.3648.521.04NS48.8049.430.77
Maxillary intercanine width35.4935.890.82NS36.6636.810.31
Mandibular intercanine width26.5926.860.6627.1827.470.81

 TriosZfx IntraScan
 Model BModel LSignificantModel BModel LSignificant

Maxillary intermolar width54.6654.770.64NS54.4754.972.47NS
Mandibular intermolar width48.9449.230.6849.1249.631.98NS
Maxillary intercanine width36.2436.660.50NS36.4936.610.70NS
Mandibular intercanine width27.4127.540.31NS27.1027.091.98NS

Model B: median measurement of model B.
Model L: median measurement of model L.
: difference of maximum and minimum measurements among 10 images of buccal and lingual models, which refers to the largest distortion according to buccal and lingual brackets.
(Mann–Whitney test).
NS: not significant.