Research Article
Experimental Model of Proximal Junctional Fracture after Multilevel Posterior Spinal Instrumentation
Figure 5
Graph showing the measured displacement with respect to the number of cycles for specimen A, depicting the moment when the fracture occurs (circled) with a sudden increase in displacement followed by a gradual decrease.