Table of Contents Author Guidelines Submit a Manuscript
BioMed Research International
Volume 2016 (2016), Article ID 8594087, 7 pages
http://dx.doi.org/10.1155/2016/8594087
Research Article

The Effect of File Size and Type and Irrigation Solutions on the Accuracy of Electronic Apex Locators: An In Vitro Study on Canine Teeth

1Department of Biostructure and Animal Physiology, Wroclaw University of Environmental and Life Sciences, Kożuchowska 1, 51-631 Wroclaw, Poland
2Department of Conservative Dentistry and Pedodontics, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland
3Faculty of Mechanical Engineering, Technical University of Wroclaw, Łukasiewicza 5, 50-371 Wroclaw, Poland
4Dental Clinic Adentis, Surowieckiego 8, 02-785 Warszawa, Poland
5Dental Practice, Bartąska 2/22, 10-699 Olsztyn, Poland
6Private Dental Clinic Maciej Kozłowski, Spokojna 23, 56-400 Oleśnica, Poland

Received 4 April 2016; Revised 1 August 2016; Accepted 25 August 2016

Academic Editor: Andrea Scribante

Copyright © 2016 Maciej Janeczek et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. M. Janeczek, W. Janeczek, and M. Dzięcioł, “Przypadek rozległych urazów w jamie ustnej psa spowodowanych nożem kosiarki,” Magazyn Weterynaryjny, vol. 16, pp. 14–15, 2007. View at Google Scholar
  2. M. Janeczek, B. Kupiec, A. Sender-Janeczek, W. Janeczek, and A. Chrószcz, “The clinical evaluation of fillings made witch Ketac-Cem® after endodontic treatment in dogs,” Polish Journal of Veterinary Sciences, vol. 13, no. 3, pp. 533–536, 2010. View at Google Scholar · View at Scopus
  3. F. W. Garcia de Paula-Silva, B. Hassan, L. A. Bezerra da Silva, M. R. Leonardo, and M.-K. Wu, “Outcome of root canal treatment in dogs determined by periapical radiography and cone-beam computed tomography scans,” Journal of Endodontics, vol. 35, no. 5, pp. 723–726, 2009. View at Publisher · View at Google Scholar · View at Scopus
  4. M. Janeczek and W. Janeczek, “Pourazowa martwica miazgi u psów—rozpoznanie i leczenie zachowawcze,” Magazyn Weterynaryjny, vol. 14, pp. 24–25, 2005. View at Google Scholar
  5. M. Janeczek, W. Janeczek, A. Sender-Janeczek, and R. Henklewski, “Postępowanie w przypadku złamania kła z długotrwałą ekspozycją miazgi zęba u psa,” Acta Scientiarum Polonorum Medicina Veterinaria, vol. 3, pp. 37–43, 2004. View at Google Scholar
  6. B. B. Marroquín, M. A. A. El-Sayed, and B. Willershausen-Zönnchen, “Morphology of the physiological foramen: I. Maxillary and mandibular molars,” Journal of Endodontics, vol. 30, no. 5, pp. 321–328, 2004. View at Publisher · View at Google Scholar · View at Scopus
  7. A. Kustarci, D. Arsian, and D. Altunbag, “In vitro comparison of working length determination using three different electronic apex locators,” Dental Research Journal, vol. 11, pp. 568–573, 2014. View at Google Scholar
  8. A. K. Ebrahim, T. Yoshioka, C. Kobayashi, and H. Suda, “The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: an in vitro study,” Australian Dental Journal, vol. 51, no. 2, pp. 153–157, 2006. View at Publisher · View at Google Scholar · View at Scopus
  9. K. Raghu, J. G. Daniel, S. Razvi, R. Vinaychandra, A. Kini, and K. J. Nandakishore, “In vivo evaluation of the accuracy of working length determination using an electronic apex locater IPEX (NSK) on vital uninfected teeth and teeth with radiographic evidence of periapical lesions,” Journal of International Society of Preventive and Community Dentistry, vol. 4, no. 6, pp. 204–208, 2014. View at Publisher · View at Google Scholar
  10. Z. Jańczuk, U. Kaczmarek, and M. Lipski, Stomatologia zachowawcza. Zarys kliniczny, Wydawnictwo Lekarskie PZWL, Warsaw, Poland, 2014.
  11. L. Santhosh, P. Raiththa, S. Aswathanarayana, S. Panchajanya, J. T. Reddy, and S. R. Susheela, “Influence of root canal curvature on the accuracy of an electronic apex locator: an in vitro study,” Journal of Conservative Dentistry, vol. 17, no. 6, pp. 583–586, 2014. View at Publisher · View at Google Scholar · View at Scopus
  12. B. Briseño-Marroquín, S. Frajlich, F. Goldberg, and B. Willershausen, “Influence of instrument size on the accuracy of different apex locators: an in vitro study,” Journal of Endodontics, vol. 34, no. 6, pp. 698–702, 2008. View at Publisher · View at Google Scholar · View at Scopus
  13. I. Sunada, “New method for measuring the length of the root canal,” Journal of Dental Research, vol. 41, no. 2, pp. 375–387, 1962. View at Publisher · View at Google Scholar
  14. S. K. Kolanu, S. Varri, J. Thummu, N. Bolla, S. Vemuri, and P. Mandava, “Evaluation of correlation betweenapical diameter and file size using propex pixi apex locator,” Journal of Clinical and Diagnostic Research, vol. 8, no. 12, pp. ZC18–ZC20, 2014. View at Publisher · View at Google Scholar · View at Scopus
  15. M. P. J. Gordon and N. P. Chandler, “Electronic apex locators,” International Endodontic Journal, vol. 37, no. 7, pp. 425–437, 2004. View at Publisher · View at Google Scholar · View at Scopus
  16. E. Uzunoglu, A. Eymirli, M. Ö. Uyanik, S. Çalt, and E. Nagas, “Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator,” Restorative Dentistry and Endodontics, vol. 40, no. 1, pp. 44–49, 2015. View at Publisher · View at Google Scholar
  17. A. F. Fouad, E. M. Rivera, and K. V. Krell, “Accuracy of the endex with variations in canal irrigants and formane size,” Journal of Endodontics, vol. 19, no. 2, pp. 63–67, 1993. View at Publisher · View at Google Scholar · View at Scopus
  18. M. Herrera, C. Ábalos, A. J. Planas, and R. Llamas, “Influence of apical constriction diameter on root ZX Apex locator precision,” Journal of Endodontics, vol. 33, no. 8, pp. 995–998, 2007. View at Publisher · View at Google Scholar · View at Scopus
  19. M. Herrera, C. Ábalos, C. Lucena, A. Jiménez-Planas, and R. Llamas, “Critical diameter of apical foramen and of file size using the root ZX apex locator: an in vitro study,” Journal of Endodontics, vol. 37, no. 9, pp. 1306–1309, 2011. View at Publisher · View at Google Scholar · View at Scopus
  20. L. Huang, “An experimental study of the principle of electronic root canal measurement,” Journal of Endodontics, vol. 13, no. 2, pp. 60–64, 1987. View at Publisher · View at Google Scholar · View at Scopus
  21. T. J. Stein, J. F. Corcoran, and R. M. Zillich, “The influence of the major and minor foramen diameters on apical electronic probe measurements,” Journal of Endodontics, vol. 16, no. 11, pp. 520–522, 1990. View at Publisher · View at Google Scholar · View at Scopus
  22. U. Aydin, E. Karataslioglu, F. Aksoy, and C. Yildirim, “In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters,” Journal of Conservative Dentistry, vol. 18, no. 1, pp. 66–69, 2015. View at Publisher · View at Google Scholar · View at Scopus
  23. N. J. McDonald, “The electronic determination of working length,” Dental Clinics of North America, vol. 36, no. 2, pp. 293–307, 1992. View at Google Scholar · View at Scopus
  24. M. H. Nekoofar, K. Sadeghi, E. Sadighi Akha, and M. S. Namazikhah, “The accuracy of the Neosono Ultima EZ apex locator using files of different alloys: an in vitro study,” Journal of the California Dental Association, vol. 30, no. 9, pp. 681–684, 2002. View at Google Scholar
  25. J. A. Jenkins, W. A. Walker III, W. G. Schindler, and C. M. Flores, “An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants,” Journal of Endodontics, vol. 27, no. 3, pp. 209–211, 2001. View at Publisher · View at Google Scholar · View at Scopus
  26. A. C. Tinaz, L. S. Sevimli, G. Görgül, and E. G. Türköz, “The effects of sodium hypochloride concentrations on the accuracy of an apex locating device,” Journal of Endodontics, vol. 28, no. 3, pp. 160–162, 2002. View at Publisher · View at Google Scholar · View at Scopus
  27. T. F. Pilot and D. L. Pitts, “Determination of impedance changes at varying frequencies in relation to root canal file position and irrigant,” Journal of Endodontics, vol. 23, no. 12, pp. 719–724, 1997. View at Publisher · View at Google Scholar · View at Scopus
  28. O. Khattak, E. Raidullah, and M.-L. Francis, “A comparative assessment of the accuracy of electronic apex locator (Root ZX) in the presence of commonly used irrigating solutions,” Journal of Clinical and Experimental Dentistry, vol. 6, no. 1, pp. e41–e46, 2014. View at Publisher · View at Google Scholar · View at Scopus
  29. I. Khursheed, R. Bansal, T. Bansa, H. P. Singh, M. Yadav, and K. J. Reddy, “Comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: an in vivo/ex vivo study,” Dental Research Journal (Isfahan), vol. 11, pp. 56–60, 2014. View at Google Scholar