Research Article
A Novel ECG Eigenvalue Detection Algorithm Based on Wavelet Transform
Table 1
Performance evaluation on R and T waves by using first channel of MIT-BIH arrhythmia database.
| ECG record | Total (beats) | FN_R (beats) | FN_T (beats) | FP_R (beats) | FP_T (beats) | DER_R (%) | DER_T (%) | Se_R (%) | Se_T (%) | Accuracy_R (%) | Accuracy_T (%) |
| 200 | 2601 | 1 | 1 | 6 | 8 | 0.27 | 0.35 | 99.96 | 99.96 | 99.73 | 99.65 | 201 | 1963 | 0 | 1 | 2 | 2 | 0.10 | 0.15 | 100.00 | 99.95 | 99.90 | 99.85 | 202 | 2136 | 1 | 2 | 7 | 9 | 0.38 | 0.52 | 99.95 | 99.91 | 99.63 | 99.49 | 203 | 2980 | 11 | 12 | 5 | 6 | 0.54 | 0.61 | 99.63 | 99.60 | 99.46 | 99.40 | 205 | 2656 | 1 | 1 | 0 | 1 | 0.04 | 0.08 | 99.96 | 99.96 | 99.96 | 99.92 | 207 | 1862 | 0 | 1 | 1 | 1 | 0.05 | 0.11 | 100.00 | 99.95 | 99.95 | 99.89 | 208 | 2955 | 8 | 9 | 5 | 5 | 0.44 | 0.48 | 99.73 | 99.69 | 99.56 | 99.53 | 209 | 3005 | 1 | 1 | 0 | 1 | 0.03 | 0.07 | 99.97 | 99.97 | 99.97 | 99.93 | 210 | 2650 | 6 | 7 | 3 | 4 | 0.34 | 0.42 | 99.77 | 99.74 | 99.66 | 99.58 | 215 | 3363 | 0 | 1 | 0 | 0 | 0.00 | 0.03 | 100.00 | 99.97 | 100.00 | 99.97 | 217 | 2208 | 2 | 2 | 2 | 3 | 0.18 | 0.23 | 99.91 | 99.91 | 99.82 | 99.77 | 219 | 2154 | 1 | 0 | 2 | 2 | 0.14 | 0.09 | 99.95 | 100.00 | 99.86 | 99.91 | 220 | 2048 | 1 | 1 | 1 | 1 | 0.10 | 0.10 | 99.95 | 99.95 | 99.90 | 99.90 | 223 | 2605 | 2 | 1 | 0 | 0 | 0.08 | 0.04 | 99.92 | 99.96 | 99.92 | 99.96 | 228 | 2053 | 7 | 7 | 7 | 8 | 0.69 | 0.74 | 99.66 | 99.66 | 99.32 | 99.27 | 230 | 2256 | 1 | 1 | 3 | 3 | 0.18 | 0.18 | 99.96 | 99.96 | 99.82 | 99.82 |
|
|