Research Article
Effect of Endocrown Restorations with Different CAD/CAM Materials: 3D Finite Element and Weibull Analyses
Table 1
Material properties that were assigned to dental tissues, surrounding structure, and restorative materials used [
1,
2,
17–
20].
| | Young’s modulus (MPa) | Poisson ratio () | Characteristic strength (MPa) | Weibull modulus () | References |
| Enamel | 84100 | 0.33 | 42.41 | 5.53 | [1, 17] | Dentin | 18600 | 0.32 | 44.45 | 3.35 | [1, 17] | Vita Blocks Mark II | 71300 | 0.23 | 118.65 | 19.90 | [18] | Lava Ultimate | 12700 | 0.45 | 300.64 | 10.90 | [18] | Vita Enamic | 37800 | 0.24 | 193.45 | 18.80 | [18] | Spongious Bone | 1370 | 0.3 | | | [2] | Cortical Bone | 10700 | 0.3 | | | [19] | Periodontal ligament | 68.9 | 0.45 | | | [2] | Gutta Percha | 0.69 | 0.45 | | | [20] |
|
|