Research Article
Bending Properties of Fiber-Reinforced Composites Retainers Bonded with Spot-Composite Coverage
Table 2
Descriptive statistics (
) of load values of the 8 groups tested (each group consisted of 10 specimens).
| Group | Code | Material | Shape | Bonding | Deflection | Mean | SD | Min | Mdn | Max | Post hoc |
| 1 | FW | Stainless steel | Flat wire | Spot bonded | 0.1 mm | 8.33 | 1.68 | 6.19 | 8.90 | 10.76 | A | 2 | RW | Stainless steel | Round wire | Spot bonded | 0.1 mm | 4.24 | 1.16 | 3.23 | 3.84 | 6.66 | A | 3 | FS | FRC | Fiber bundle | Spot bonded | 0.1 mm | 16.67 | 2.08 | 13.53 | 16.18 | 19.33 | A | 4 | FF | FRC | Fiber bundle | Full bonded | 0.1 mm | 41.73 | 16.16 | 12.18 | 44.52 | 58.64 | B, C, D | 5 | FW | Stainless steel | Flat wire | Spot bonded | max load | 34.96 | 6.76 | 22.86 | 35.79 | 44.86 | B | 6 | RW | Stainless steel | Round wire | Spot bonded | max load | 35.62 | 10.26 | 21.22 | 38.19 | 50.74 | B | 7 | FS | FRC | Fiber bundle | Spot bonded | max load | 41.44 | 9.19 | 29.31 | 40.32 | 53.46 | B, D | 8 | FF | FRC | Fiber bundle | Full bonded | max load | 52.93 | 18.84 | 15.24 | 57.88 | 74.12 | C, D |
|
|
Mean with same letters is not significantly different.
|