Research Article

Bending Properties of Fiber-Reinforced Composites Retainers Bonded with Spot-Composite Coverage

Table 2

Descriptive statistics () of load values of the 8 groups tested (each group consisted of 10 specimens).

GroupCodeMaterialShapeBondingDeflectionMeanSDMinMdnMaxPost hoc

1FWStainless steelFlat wireSpot bonded0.1 mm8.331.686.198.9010.76A
2RWStainless steelRound wireSpot bonded0.1 mm4.241.163.233.846.66A
3FSFRCFiber bundleSpot bonded0.1 mm16.672.0813.5316.1819.33A
4FFFRCFiber bundleFull bonded0.1 mm41.7316.1612.1844.5258.64B, C, D
5FWStainless steelFlat wireSpot bondedmax load34.966.7622.8635.7944.86B
6RWStainless steelRound wireSpot bondedmax load35.6210.2621.2238.1950.74B
7FSFRCFiber bundleSpot bondedmax load41.449.1929.3140.3253.46B, D
8FFFRCFiber bundleFull bondedmax load52.9318.8415.2457.8874.12C, D

Mean with same letters is not significantly different.