Research Article

A Comparative Study for Detection of EGFR Mutations in Plasma Cell-Free DNA in Korean Clinical Diagnostic Laboratories

Table 5

Comparison of mutant allelic frequency from two laboratories using different next-generation sequencing platforms.

Samplep.L858Rp.E746_A750del (exon 19 deletion)p.T790Mp.A767_V769dup (exon 20 insertion)
Expected mutant allele frequency (%)Lab FLab CExpected mutant allele frequency (%)Lab FLab CExpected mutant allele frequency (%)Lab FLab CExpected mutant allele frequency (%)Lab FLab C
Molecular coverage depth, total/mutant (allele frequency, %)Read coverage depth, total/mutant (allele frequency, %)Read coverage depth, total/mutant (allele frequency, %)Molecular coverage depth, total/mutant (allele frequency, %)Read coverage depth, total/mutant (allele frequency, %)Read coverage depth, total/mutant (allele frequency, %)Molecular coverage depth, total/mutant (allele frequency, %)Read coverage depth, total/mutant (allele frequency, %)Read coverage depth, total/mutant (allele frequency, %)Molecular coverage depth, total/mutant (allele frequency, %)Read coverage depth, total/mutant (allele frequency, %)Read coverage depth, total/mutant (allele frequency, %)

Level 14.291970/67 (3.40)74088/2440 (3.29)4594/171 (3.72)5.193360/131 (3.90)60991/1272 (2.09)5819/231 (3.97)4.013182/124 (3.90)59366/2276 (3.83)1717/71 (4.14)3.853258/130 (3.99)38689/1707 (4.41)1091/30 (2.75)
Level 22.131755/41 (2.34)70894/1707 (2.41)4385/84 (1.92)2.132855/65 (2.28)61723/753 (1.22)10001/130 (1.30)2.052680/51 (1.90)56596/983 (1.74)2572/87 (3.38)1.942670/53 (1.99)37564/541 (2.37)2341/24 (1.03)
Level 30.801912/15 (0.78)107664/791 (0.73)4681/52 (1.11)1.103095/22 (0.71)94144/378 (0.40)9416/57 (0.61)0.812902/26 (0.90)84166/754 (0.90)0.723667/21 (0.57)57591/541 (0.94)
Level 40.121804/0 (ND)70849/0 (ND)0.103158/3 (0.09)73836/114 (0.15)0.112980/0 (ND)65455/0 (ND)0.053296/3 (0.09)49234/115 (0.23)
Precision materials (P-1~P-33.002250/89 (3.96)97519/3743 (3.84)4067/148 (3.64)3.002306/68 (2.95)45162/1336 (2.96)9157/250 (2.73)3.003132/126 (4.02)60226/1396 (2.32)2131/111 (5.21)----
3.002259/94 (4.16)124662/5042 (4.04)6335/344 (5.43)3.003326/114 (3.43)110580/3431 (3.1)8823/274 (3.11)3.002980/112 (3.76)88684/3164 (3.57)2904/126 (4.34)----
3.002200/72 (3.27)87890/2799 (3.18)4638/139 (2.99)3.003462/134 (3.87)81882/1905 (2.33)14136/242 (1.71)3.003380/123 (3.64)89937/3303 (3.67)----

depth was not provided by the laboratory. positive results from precision materials were summarized in the table. measurement of P-1 material showed invalid result using next-generation sequencing from a laboratory. ND, not detected.