Research Article
Clinical Influence of Micromorphological Structure of Dental Implant Bone Drills
Table 1
Crosstab manufacturer versus mean model parameters, significant difference, cut-off 0.08mm.
Manufacturer
versus
model parameter
A
B
C
D
E
Significant difference
Rq
0.10
1.01
0.77
8.61
2.17
A-B, A-C, A-D, B-D, C-D, E-D
Rz
0.38
2.85
1.965
21.405
3.80
A-B, A-C, A-D, A-E, B-D, C-D, E-D
Rmr
99.00
33.27
4.17
1.37
1.53
A-B, A-C, A-D, A-E
Rku
2.73
3.00
1.97
3.43
1.73
A-E, B-E, C-D, D-E
Psm
28.00
76.67
190.00
53.67
101.50
A-B, A-C, A-E, B-C, C-D, C-E
Rsk
-0.05
-0.46
0.58
0.46
-0.18
A-C, A-D, B-C, B-D, C-E