Research Article
Mandibular Flexure and Peri-Implant Bone Stress Distribution on an Implant-Supported Fixed Full-Arch Mandibular Prosthesis: 3D Finite Element Analysis
Table 1
Mechanical properties of modelled materials and structures used for three-dimensional finite analysis.
| Material | Structure | Young’s modulus (GPA) | Poisson’s ratio | References |
| Titanium | Implant | 110.0 | 0.35 | Sevimay et al., 2005 [23] | Titanium alloy | Abutment | 107.2 | 0.33 | Suansuwan and Swain, 2001 [24] | Cr-Co alloy | Framework prosthesis | 218.0 | 0.33 | Anusavice and Coscone, 2003 [25] | Feldspathic porcelain | Veneered framework prosthesis | 68.9 | 0.28 | Geng et al., 2001 [8] | Cortical bone | Peri-implant bone | 13.70 | 0.30 | Borchers and Reichart, 1983 [26] | Cancellous bone | Peri-implant bone | 1.37 | 0.31 | Borchers and Reichart, 1983 [26] |
|
|