Research Article

Evaluation of Automatic Blood Analyzer as Screening Method in Fetomaternal Hemorrhage

Table 2

Comparison between flow cytometry (FCM) and automatic blood analyzer (ABA) for screening of fetal maternal hemorrhage (FMH) in puerperal women (n=40). Thresholds were specified for FCM and ABA following the assessment of blood samples of male adults added with fetal blood. Blood samples were prepared by serially diluting umbilical cord blood in blood of male adults at dilutions 1/10, 1/100, 1/1,000, and 1/10,000.

All dilutions1:101:1001:1.0001:10.000
ABAABAABAABAABA
Threshold< 0.500≥ 0.500TotalThreshold< 2.500≥ 2.500TotalThreshold<0.500≥ 0.500TotalThreshold< 2.500≥ 2.500TotalThreshold< 0.500≥ 0.500Total

FCM< 0,0945271138< 3,02032840< 0,450291140< 0,09630838< 0,061221133
≥ 0,0945202≥ 3,020000≥ 0,450000≥ 0,096202≥ 0,061707
Total291140Total32840Total291140Total32840Total291140