Research Article

Can Preoperative 3D Printing Change Surgeon’s Operative Plan for Distal Tibia Fracture?

Table 3

Change of plate selection for complex distal tibia fracture after using 3D models.

Changed numbers (%)Not changed numbers (%)Total numbers

Inexperienced group42 (74%)15 (26%)57
Experienced group14 (31%)31 (69%)45

Inexperienced group: orthopedic surgeons who have operated less than 15 cases of distal tibia fracture.