Research Article

Assessment of Airborne Bacterial and Fungal Communities in Selected Areas of Teaching Hospital, Kandy, Sri Lanka

Table 1

Levels of total airborne microbial load in each sampling site (cells × 106 /m2).

Sampling Sites9.00 am–10.00 am12.00 noon–1.00 pm2.00 pm–3.00 pm5.00 pm–6.00 pmMean value in each site ± SD (whole sampling period)

Outpatients Department8.898.1910.58.499.01 ± 1.01
Respiratory Diseases Unit–Female Ward7.434.688.425.616.54 ± 1.70
Respiratory Diseases Unit–Male Ward3.863.636.146.024.91 ± 1.35
Respiratory Diseases Unit–Staff Room6.735.329.946.497.12 ± 1.98
Respiratory Diseases Unit–Bronchoscopy Unit4.503.579.245.445.69 ± 2.49
Operating Theatre in Obstetrics/Gynecology Department3.514.217.194.974.97 ± 1.60
Surgical Intensive Care Unit4.212.115.853.393.89 ± 1.57
Control5.034.216.615.325.29 ± 0.99