Clinical Study

Clinical Performance of the Automated LIAISON® Meridian H. pylori SA Stool Antigen Test

Table 3

Comparison of results obtained by biopsy methods and the LIAISON® Meridian H. pylori SA assay for the assessment of H. pylori infection.

LIAISON® Meridian H. pylori SA
PositiveNegativeEquivocal

Histopathology
 Positive67 (24.2%)64 (23.1%)3 (1.1%)0
 Negative210 (75.8%)3 (1.1%)205 (74.0%)2 (0.7%)
Culture
 Positive46 (16.6%)45 (16.2%)10
 Negative118 (42.6%)3 (1.1%)113 (40.8%)2 (0.7%)
 Not performed113 (40.8%)19 (6.9%)94 (33.9%)0
Rapid urease test
 Positive67 (24.2%)64 (23.1%)3 (1.1%)0
 Negative210 (75.8%)3 (1.1%)205 (74.0%)2 (0.7%)