Research Article

The Study of Field Equivalence Determined by the Modeled Percentage Depth Dose in Electron Beam Radiation Therapy

Table 3

The maximum ionizing depth, dose maximum depth, and mean energy in five different electron energies with , () is shown. The depth at which the dose is 50% of the maximum dose is defined as in this study.

Nominal energy (MeV) (MeV) (mm) (mm) (mm) (mm)X-ray contamination (%)

65.4111.1/12.116.923.230.20.7
98.6620.6/21.528.337.145.11.2
1211.2726.1/27.137.448.358.72.1
1514.0427.1/28.446.160.373.72.6
1817.0324.3/25.256.873.188.73.5