Research Article

Is Bridge Plating of Comminuted Humeral Shaft Fractures Advantageous When Using Compression Plates with Three versus Two Screws per Fragment? A Biomechanical Cadaveric Study

Figure 2

Setup with a specimen mounted for biomechanical testing in lateral bending (a, b), anterior bending (c), axial bending, and torsion in internal rotation (d). Arrows in (a) and (d) denote loading directions.
(a)
(b)
(c)
(d)