Motor Organization in Schizencephaly: Outcomes of Transcranial Magnetic Stimulation and Diffusion Tensor Imaging of Motor Tract Projections Correlate with the Different Domains of Hand Function
Table 3
Hand function test results of patients with schizencephaly.
Case no.
More paretic hand
HFT ratio
Grip (kg; paretic : less paretic)
B&B (; paretic : less paretic)
9-hole (sec; paretic : less paretic)
1
Lt
0.21 (7 : 34)
0.53 (31 : 58)
0.35 (46 : 16)
2
Lt
0.12 (2 : 17)
0.61 (25 : 41)
0.06 (408 : 23)
3
Lt
0.09 (0.5 : 5.5)
0.38 (8 : 21)
0.19 (NT : 93)
4
Rt
0.1 (0.4 : 4)
0.62 (18 : 29)
0.33 (79 : 26)
5
Rt
0.29 (4 : 14)
0.38 (15 : 40)
0.12 (173 : 20)
6
Lt
0.5 (9 : 18)
0.67 (14 : 21)
0.26 (140 : 37)
7
Rt
0.25 (1 : 4)
0.71 (37 : 52)
0.42 (66 : 28)
8
Lt
0.33 (4 : 12)
0.25 (10 : 40)
0.05 (NT : 23)
9
Rt
0.66 (4 : 6)
0.24 (6 : 25)
0.15 (NT : 76)
10
Rt
0.55 (2.2 : 4)
NP
0.09 (NT : 47)
11
Lt
0.81 (13 : 16)
0.94 (17 : 18)
0.24 (225 : 54)
12
Lt
0.35 (3 : 8.6)
0.43 (19 : 44)
0.10 (260 : 27)
HFT: hand function test; B&B: box and block test; Grip: grip strength test; 9-hole: 9-hole peg test; Rt: right; Lt: left; kg: kilogram; : number of blocks; sec: second; SD: standard deviation; NT: not testable; NP: not performed.