Research Article
Risk Factors for Complications following Volar Locking Plate (VLP) Fixation of Unstable Distal Radius Fracture (DRF)
Table 2
Multivariate analysis identifying 5 factors independently associated with complications after VLP fixation of DRF.
| Variables | OR and 95% CI | |
| Sex (male vs. female) | 3.5 (1.3 to 9.8) | 0.014 | Fracture type | | | (i) A | Reference | | (ii) B | 1.2 (0.5 to 2.7) | 0.344 | (iii) C | 2.7 (1.2 to 5.8) | 0.035 | Anesthesia mode (general vs. regional) | 2.4 (1.0 to 5.6) | 0.045 | Bone grafting | 6.3 (2.5 to 16.3) | <0.001 | Surgery performed by less experienced surgeon (vs. experienced surgeon) | 3.1 (1.6 to 5.2) | 0.003 |
|
|