Research Article

Intra- and Extracranial MR Venography: Technical Notes, Clinical Application, and Imaging Development

Table 1

Technical parameters for MRV two-tier protocol, with (a) and without (b) contrast administration.
(a)

4D TRAK2D PC neck

TRTI 4.510
TE1.616.2
Matrix428 × 217120 × 84
Acquisition voxel0.72/0.721.00/1.43/5.00
Reconstruction voxel0.55/0.55/0.600.47/0.47/5.00
Number of slices1201
NSA2
PC/VENC (cm/s)/50
WFS (Pix)/BW (Hz)0.502/432.71.134/191.6
SENSE (PAT)RL 2.5 /
Acquisition time (min)0:572:49 (2x)

(b)

3D PC brain 2D TOF neck2D PC neck

TRTI201710
TE5.53.36.2
Matrix232 × 220224 × 224120 × 84
Acquisition voxel0.99/1.04/4.0 0.89/0.89/31.00/1.43/5.00
Reconstruction voxel0.9/0.9/2.00.39/0.39/30.47/0.47/5.00
Number of slices801101
NSA112
PC/VENC (cm/s)15 /50
WFS (Pix)/BW (Hz)1.145/189.71.270/171.01.134/191.6
SENSE (PAT)AP 1.5 / /
Acquisition time7:507:252:49 (2x)