Research Article
Determination of Coverage Interval of Antioxidant Vitamins (Vitamin C & Vitamin E) in Plasma and Serum of Bengali Population
Table 1
Showing the inhouse performance parameter of the spectrophotometric methods of Vitamin C and α-tocopherol.
| Name of the Analyte | Performance Parameter | Percentage (%) |
| Vitamin C | Precision | 6 | Recovery Analysis from Spike sample | 90.55 | Proportional Error | 9.45 (<23.8%, Total allowable error) [16] | Sensitivity () | 0.9965 |
| α-tocopherol | Precision | 6.65 | Recovery Analysis from Spike sample | 92 | Proportional Error | 8 (<16.5%, Total allowable error) [16] |
|
|