The Performance of Equations That Estimate Glomerular Filtration Rate against Measured Urinary Creatinine Clearance in Critically Ill Patients

Table 3

Predictive performance of equations estimating glomerular filtration rate compared with creatinine clearance (CrCl24h-urine) measured by 24-hour urine collection.

CrCl24h-urineCGactual-wtCGideal-wtCGadjusted-wtMDRD-4MDRD-6CKD-EPIJelliffe

Data from the first 237 urine collections (all 237 patients)
GFR estimate (mlH/min) ±SD108.4 ± 68.9129.6 ± 65.6113.5 ± 59.2119.9 ± 59.9108.9 ± 52.5102.2 ± 48.7102.1 ± 40.4102.0 ± 49.3
Coefficient of variation (%)63.650.652.250.048.247.739.648.3
Correlation0.770.710.750.630.620.670.66
Bias (ml/min)21.15.011.50.5−10.5−6.3−6.4
Precision (ml/min)±46.0±49.9±45.9±54.2±53.9±51.6±51.9
Error (%)77.390.080.499.7100.498.098.6
Accuracy
 ±15%12.727.430.025.722.828.325.7
 ±30%49.448.151.248.947.448.949.4
 ±50%66.772.271.369.275.170.557.4

Data from the 453 urine collections (all 237 patients)
GFR estimate (ml/min) ±SD102.7 ± 65.4130.1 ± 65.9114.9 ± 60.2121.0 ± 60.6109.8 ± 52.199.8 ± 47.1103.2 ± 40.0103.2 ± 49.3
Coefficient of variation (%)63.750.752.450.147.447.238.847.8
Correlation0.790.750.790.670.660.670.70
Bias (ml/min)27.412.318.37.1−5.70.530.53
Precision (ml/min)±43.0±44.3±40.9±49.1±49.3±47.2±46.8
Error (%)73.981.573.292.596.191.890.9

Accuracy
 ±15%24.127.829.126.727.528.026.7
 ±30%42.847.549.249.950.550.350.8
 ±50%60.069.366.269.373.569.872.2

Urine collections with CrCl24h-urine< 30 ml/min (N= 72)
GFR estimate (ml/min) ±SD13.3 ± 8.439.7 ± 25.730.8 ± 25.734.4 ± 25.634.4 ± 33.332.1 ± 28.438.2 ± 30.633.7 ± 27.9
Coefficient of variation (%)63.264.783.474.496.888.580.182.8
Correlation0.580.500.540.550.580.560.54
Bias (ml/min)26.417.621.121.118.725.020.4
Precision (ml/min)±21.9±22.7±21.8±29.5±24.4±26.9±24.4

Accuracy
 ±15%1.416.75.612.513.111.18.3
 ±30%6.923.615.326.427.923.619.4
 ±50%11.136.123.636.139.330.631.9

Urine collections with CrCl24h-urine30–59.9 ml/min (N=68)
GFR estimate (ml/min) ±SD45.3 ± 8.685.6 ± 34.576.9 ± 37.380.4 ± 35.484.8 ± 40.673.8 ± 36.586.3 ± 29.576.0 ± 35.3
Correlation0.440.460.460.300.460.350.33
Coefficient of variation (%)19.040.348.544.047.949.534.246.4
Bias (ml/min)40.331.635.139.528.441.030.6
Precision (ml/min)±31.7±34.3±32.4±38.9±33.5±27.6±33.5

Accuracy
 ±15%5.911.814.77.415.57.411.8
 ±30%16.226.525.020.632.814.735.3
 ±50%27.944.139.738.253.423.551.5

Urine collections with CrCl24h-urine 60–129.9 ml/min (N=156)
97.8 ± 20.5134.2 ± 44.5121.6 ± 43.8126.6 ± 41.9120.8 ± 37.6107.7 ± 35.5114.2 ± 26.4111.7 ± 36.2
Coefficient of variation (%)21.033.236.033.131.133.023.132.4
Correlation0.370.380.400.120.180.320.23
Bias (ml/min)36.423.828.823.09.616.413.9
Precision (ml/min)±41.6±40.6±38.7±40.7±37.6±20.7±37.2

Accuracy
 ±15%24.427.629.527.632.642.328.8
 ±30%44.246.249.453.854.561.555.8
 ±50%66.771.869.272.473.184.078.8

Urine collection with CrCl24h-urine> 130 ml/min (N=157)
GFR estimate (ml/min) ±SD173.3 ± 41.6186.6 ± 44.2163.3 ± 37.6172.6 ± 34.3144.1 ± 32.3130.3 ± 30.5129.4 ± 16.3138.4 ± 31.3
Coefficient of variation (%)24.023.723.019.922.423.412.622.6
Correlation0.290.200.280.220.140.140.20
Bias (ml/min)13.3−10.0−0.7−29.2−43.7−44.0−34.9
Precision (ml/min)±51.3±50.0±45.8±46.7±48.2±42.5±46.8

Accuracy
 ±15%42.040.145.940.833.130.639.5
 ±30%69.468.875.269.457.466.966.9
 ±50%89.893.094.394.988.593.693.0

CKD-EPI: chronic kidney disease epidemiology collaboration; CG: Cockroft-Gault; CrCl24h-urine: creatinine clearance measured by 24-hour urine collection; GFR: glomerular filtration rate; MDRD: modification of diet in renal disease study; SD: standard deviation. CGactual-wt: the CG equation was calculated using actual body weight. CGideal-wt: the CG equation was calculated using ideal body weight. CGadjusted-wt: the CG equation was calculated using adjusted body weight. MDRD-4: the MDRD equation was calculated using four variables. MDRD-6: the MDRD equation was calculated using six variables. using one-sided t test indicating that the bias was significant.