Research Article

A Fuzzy Logic System for Seizure Onset Detection in Intracranial EEG

Table 5

Summary of the results: sensitivity in percentage, false detection rates per hour, and average detection latencies in seconds.

PatientNo. of seizuresData Length (h)SEN (%)FDR/h (uninteresting)FDR/h (interesting)Detection Latency (s)

132.4866.674.40.407.21
225.161002.520.3925.03
345.10750.190.198.72
435.8710010.1727.43
523.811000.260.2623.97
624.131000.72012.64
723.911001.02017.46
823.491001.430.5755.46
958.831001.240.34−24.92
1134.921001.010.40−6.84
1247.87752.160.5021.04
1323.921000.510−37.69
1434.911000.610.2040.14
1525.921000027.37
1649.831003.861.015.64
17514.591000.06023.52
1811.961001.0200.31
1925.921000.3301.33
2036.871000.430.1427.07
2122.961004.720.6761.42

Total56112.4595.831.370.2615.81