Research Article

Fuzzy Inference System Approach for Locating Series, Shunt, and Simultaneous Series-Shunt Faults in Double Circuit Transmission Lines

Table 4

test for fault location error for different types of fault.

Fault typeParametersRange of percentage of error
0% to ±2%±2% to ±5%

LG420140
437.333122.666
0.686 2.449

LLG440120
437.333122.666
0.016 0.057

LL520140
515.428144.571
0.040 0.148

LLL26060
249.90470.095
0.407 1.453