Research Article
Fault Diagnosis for Analog Circuits by Using EEMD, Relative Entropy, and ELM
Table 4
Results of fault classification of the Sallen-Key filter for single faults.
| Fault number | Fault name | Test accuracy | Proposed | Wavelet [3] + ELM | Lifting wavelet [18] + ELM | [11] + ELM |
| F0 | No-fault | 1.0000 | 0.8600 | 1.0000 | 1.0000 | F1 | R1 | 0.9700 | 0.9800 | 1.0000 | 0.9800 | F2 | R1 | 1.0000 | 0.8700 | 1.0000 | 1.0000 | F3 | R2 | 1.0000 | 1.000 | 1.0000 | 0.9300 | F4 | R2 | 1.0000 | 0.9800 | 1.0000 | 1.0000 | F5 | R3 | 1.0000 | 0.8700 | 1.0000 | 1.0000 | F6 | R3 | 0.9700 | 0.7800 | 0.9500 | 0.8200 | F7 | R4 | 0.9900 | 0.9400 | 1.0000 | 1.0000 | F8 | R4 | 1.0000 | 0.8400 | 1.0000 | 1.0000 | F9 | R5 | 1.0000 | 0.9600 | 1.0000 | 1.0000 | F10 | R5 | 1.0000 | 0.8200 | 1.0000 | 1.0000 | F11 | C1 | 1.0000 | 0.8000 | 1.0000 | 1.0000 | F12 | C1 | 0.9700 | 0.6400 | 0.9400 | 0.9600 | F13 | C2 | 1.0000 | 1.0000 | 1.0000 | 1.0000 | F14 | C2 | 1.0000 | 0.9800 | 1.0000 | 1.0000 | Average accuracy | 0.9940 | 0.8880 | 0.9930 | 0.9790 |
|
|