Research Article
Multifocus Image Fusion Using Wavelet-Domain-Based Deep CNN
Table 2
Quality assessment of multifocus image “lab.”
| | MI | AG | SSIM | CEIF |
| NSCT | 6.8302 | 9.3549 | 0.4831 | 0.4080 | SR | 7.0283 | 9.4561 | 0.4778 | 0.4088 | NSCT-SR | 6.8736 | 9.5427 | 0.4986 | 0.4004 | GF | 7.9061 | 9.5579 | 0.5122 | 0.4043 | MWG | 8.5083 | 9.5019 | 0.5096 | 0.4103 | DSIFT | 8.5154 | 9.4468 | 0.5049 | 0.4112 | DCNN | 8.5826 | 9.8892 | 0.5018 | 0.4079 | PCNN | 8.5987 | 9.7017 | 0.5075 | 0.4074 | OUR | 8.6348 | 10.3541 | 0.5098 | 0.4462 |
|
|
The two best results are indicated in italics and bold.
|