Research Article
A Lightweight Dangerous Liquid Detection Method Based on Depthwise Separable Convolution for X-Ray Security Inspection
Table 6
The detection results of the different methods on the XD-N.
| Method | MIOU | MAP (%) | AP(%) | H2SO4 | HCL | C7H8 | CH3OH | CH3COCH3 | C2H5OH |
| YOLOV4_tiny_MobileNetV2_X-ray | 0.824 | 83.75 | 97.62 | 90.89 | 68.71 | 83.63 | 73.91 | 87.73 | YOLOV4_tiny_MobileNetV3_X-ray | 0.835 | 84.12 | 95.18 | 90.91 | 66.44 | 88.03 | 75.24 | 88.89 | DLDX_MobileNetV2 | 0.876 | 89.14 | 97.56 | 94.86 | 86.64 | 80.84 | 84.47 | 90.44 | DLDX_MobileNetV3 | 0.876 | 90.56 | 100 | 92.80 | 84.14 | 85.60 | 89.77 | 91.05 | DLDX | 0.876 | 90.96 | 100 | 94.57 | 88.03 | 85.59 | 87.28 | 90.27 |
|
|