Synchronous grouting ratio and performance parameters.

P. O42.5 cement (kg)Grade II fly ash (kg)Bentonite (kg)Fine sand (kg)Water-reducing agent (kg)Drinking water (kg)Setting time (h)Decantation rate (%)Stone rate (%)Consistency (cm)Final setting strength (MPa)

2002008012505.34706397113.9