Research Article

Spleen Stiffness for Predicting Varices Needing Treatment: Comparison between Two Different Elastography Techniques (Point vs. 2D-SWE)

Table 3

Classification of subjects according to the optimal, rule-out, and rule-in SSM cut-off values.

ā€‰SSM (kPa)Correctly classified (%) valueMisclassified (%) value

Optimal2D-SWE76.524.5
pSWE79.620.4

Rule-out2D-SWE964.0
pSWE92.17.9

Rule-in2D-SWE82.617.4
pSWE89.310.7

SSM: spleen stiffness measurements; Se: sensitivity; Sp: specificity; PPV: positive predictive value; NPV: negative predictive value; and AUROC: area under a receiver operating curve. Cut-off values with the higher sum of sensitivity and specificity were chosen. Cut-off values that optimized sensitivity were chosen. Cut-off values that optimized specificity were chosen.