Authors | Hybrid imaging modality (scanner) | Radiotracer injected activity | Time interval (in minutes) between radiotracer injection and image acquisition | Image analysis | Verification of PET findings | Other imaging performed for comparison |
|
Ahmadi Bidakhvidi et al. [22] | PET/CT (GE Discovery MI-4 or Siemens Biograph TruePoint) | 3 MBq/kg | 81 ± 16 | Visual | NR | — |
|
Dietlein et al. [23] | PET/CT (Siemens Biograph mCT 128 Flow) | 343 ± 49 MBq | 120 | Visual | Histology or follow-up | 68Ga-PSMA-11, 18F-DCFPyL or 18F-JK-PSMA-7 PET/CT |
|
Giesel et al. [24] | PET/CT (Siemens Biograph mCT Flow) | 251.5 (154-326) MBq | 63 ± 6 and 180 ± 5 | Visual and semiquantitative (SUV) | NR | — |
|
Giesel et al. [25] | PET/CT (Siemens Biograph mCT/mCT20 or mCT Flow) | 301 ± 46 MBq | 92 ± 26 | Visual | NR | — |
|
Liu et al. [26] | PET/MRI (Siemens Biograph mMR) | 263 (164–353) MBq | 60 | Visual | NR | — |
|
Morawitz et al. [27] | PET/CT (Siemens Biograph mCT 128) | 229 ± 27 MBq | 120 | Visual | Histology or follow-up | CT |
|
Rahbar et al. [28] | PET/CT (Siemens mCT) | 4 MBq/kg 336.7 ± 46 MBq | 60 and 120 | Visual and semiquantitative (SUV) | NR | — |
|
Rahbar et al. [29] | PET/CT (Siemens mCT) | 4 MBq/kg 338 ± 44.31 MBq | 120 | Visual and semiquantitative (SUV) | NR | — |
|
Rauscher et al. [30] | PET/CT (Siemens Biograph mCT) | 325 ± 40 MBq | 94 ± 22 | Visual and semiquantitative (SUV) | Histology or follow-up | 68Ga-PSMA-11 PET/CT |
|
Sachpekidis et al. [31] | PET/CT (Siemens Biograph mCT 128 S) | 237 (131–266) MBq | Dynamic part from 0 to 60 and static part at 70 | Visual, semiquantitative (SUV) and quantitative | NR | — |
|
Sprute et al. [32] | PET/CT (Siemens Biograph mCT/mCT Flow or GE Discovery 710) | 270 (106-356) MBq | 90 (47–169) | Visual | Histology | — |
|
Watabe et al. [33] | PET/CT (GE Discovery 710) | 259 ± 37 MBq | 57.7 ± 4.9 | Visual | Histology or follow-up | — |
|
Witkowska-Patena et al. [34] | PET/CT (GE Discovery 710) | 296 ± 14 MBq | 95 ± 12 | Visual and semiquantitative (SUV) | NR | 18F-choline PET/CT |
|
Witkowska-Patena et al. [35] | PET/CT (GE Discovery 710) | 295.5 ± 14.1 MBq | 95 ± 12 | Visual and semiquantitative (SUV) | Histology or follow-up | — |
|
Wondergem et al. [36] | PET/CT (Siemens Biograph‐16 TruePoint) | 324 (239–363) MBq | 90 | Visual | Histology or follow-up | 18F‐DCFPyL PET/CT |
|