Research Article
Comparison of the Value of Conventional Ultrasound and Contrast-Enhanced Ultrasound-Guided Puncture Biopsy in Different Sizes of Peripheral Pulmonary Lesions
Table 3
Related indicators of biopsy for the ≥30 mm group.
Group
Success rate of single puncture
Success rate of puncture
Needle bleeding rate
Pneumothorax rate
Conventional ultrasound group
70.3% (26/37)
78.4% (29/37)
10.8% (4/37)
10.8% (4/37)
Contrast-enhanced ultrasound group
97.1% (34/35)
97.1% (34/35)
2.9% (1/35)
5.7% (2/35)
X
2
value/
t
value
7.517
4.202
0.745
0.126
P
value
0.006
0.04
0.388
0.722