Research Article

Improved DCT-Based Nonlocal Means Filter for MR Images Denoising

Table 1

Comparisons of experimental results in PSNR.

Test imagesAlgorithmsNoise level (dB)
3%6%9%12%15%18%

T1-weighted MR imageNoisy29.8624.321.2619.5618.3517.44
NLM (h) 32.21 (34.38)26.73 (62.94)23.44 (92.46)21.14 (122.24)19.61 (152.12)18.36 (182.04)
UNLM (h) 32.8 (34.38)27.46 (62.94)24.14 (92.46)21.9 (122.3)20.3 (152.12)19.02 (182.06)
UNLM-DCT (h,d) 33.02 (34,17)27.92(62.48,12)24.9 (92.08,12)22.76 (121.86,12)21.05 (151.74,12)20.16 (181.26,3)

T2-weighted MR imageNoisy30.4825.2122.4420.6619.418.45
NLM (h) 32.3 (34.62)27.3 (63.02)24.32 (92.54)22.27 (122.3)20.8 (152.18)19.68 (182.06)
UNLM (h) 32.7 (34.62)27.79 (63.02)24.83 (92.62)22.8 (122.36)21.36 (152.18)20.19 (182.06)
UNLM-DCT (h,d) 32.77 (34.32,25)28.13 (62.64,13)25.53 (92.16,11)23.73 (121.86,8)22.49 (151.56,4)21.56 (181.44,3)

PD-weighted MR imageNoisy30.5225.2322.4320.6119.3118.33
NLM (h) 32.9 (34.54)27.98 (63.02)24.87 (92.54)22.7 (122.36)20.97 (152.18)19.63 (182.12)
UNLM (h) 33.36 (34.54)28.59 (63.02)25.55 (92.62)23.37 (122.36)21.57 (152.24)20.29 (182.12)
UNLM-DCT (h,d) 33.58 (34.16, 24)28.64 (62.72, 24)25.76 (91.92, 6)23.81 (121.74, 6)22.41 (151.44, 3)21.31 (181.32, 3)