Research Article

Fluid Structural Analysis of Human Cerebral Aneurysm Using Their Own Wall Mechanical Properties

Table 5

Numbering and characterization of the simulations made.

SimulationTypeElementsPressure Thickness aneurysmMaterialCoupling

1CFDTetrahedralNormal
2CSDShellNormalNormalL.E
3CSDShellH.TNormalL.E
4CSDShellNormal1/2L.E
5CSDShellNormalNormalM.R
6CSDShellH.TNormalM.R
7CSDShellNormal1/2M.R
8CSDTetrahedralNormalNormalL.E
9CSDTetrahedralNormalNormalM.R
10FSITetrahedralNormalNormalL.EComplete
11FSITetrahedralNormalNormalL.EOne direction
12FSITetrahedralNormalNormalM.RComplete
13FSITetrahedralNormalNormalM.ROne direction

H.T is hypertension blood pressure ranged between 13200 Pa and 23800 Pa. Normal pressure is the blood pressure pulse shown in Figure 5(b), L.E. is the linear elastic wall model, and M.R. is the hyperelastic Mooney-Rivlin wall model.