Computational and Mathematical Methods in Medicine / 2013 / Article / Tab 1

Research Article

Nonrigid Medical Image Registration Based on Mesh Deformation Constraints

Table 1

Comparison of the topology preservation ability between NR-MDC algorithm and DD algorithm.

AlgorithmStrategyCC Time (minutes)

NR-MDCS10.9710.5%14.8
S20.9660%15.3
S30.9840%41.7
DD0.9720.03%54.1
[20]0.9790%84.6

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.