Research Article

Improved Reconstruction Quality of Bioluminescent Images by Combining SP3 Equations and Bregman Iteration Method

Table 4

Quantitative results between the actual and the reconstructed source centers with different methods in the case of four sources.

Actual source positionReconstructed source position with SP3 methodReconstructed source position with SP3 and Bregman method

(5, −5)(5.14, −5.47)(4.96, −4.94)
(−5, −5)(−5.27, −5.34)(−4.94, −4.96)
(−5, 5)(−4.81, 5.76)(−4.95, 4.95)
(5, 5)(4.86, 5.72)(4.95, 4.95)

(5, 0)(4.98, 0.50)(4.98, 0.50)
(−5, 0)(−5.45, 0.78)(−5.49, 0.28)
(0, 5)(−0.36, 5.49)(0.14, 5.50)
(0, −5)(0.72, −5.96)(0.58, −5.47)