Research Article

A New Kernel-Based Fuzzy Level Set Method for Automated Segmentation of Medical Images in the Presence of Intensity Inhomogeneity

Table 1

Comparison of proposed method with similar approaches KFCM_FTC [8] and SFCM_LBF [13] in terms of accuracy based on Dice coefficient and CPU time in second.

MethodsImages
Accuracy % (Dice coefficient)CPU time (second)
BrainVesselHeartBreastBrainVesselHeartBreast

SFCM_LBF657567829.26.5518.9433.93
KFCM_FTC808490688.77.3614.4816.27
Proposed method9691988414.312.5626.5134.19