Research Article
The Nonsubsampled Contourlet Transform Based Statistical Medical Image Fusion Using Generalized Gaussian Density
Table 3
Objective evaluation results of the five metrics for MRI and SPECT images.
| ā | Index | DWT | GP | IHS | NSST-2 | NSST-3 | NSCT-3 | NSCT-4 | Proposed |
| Figure 8 | MI | 2.167 | 2.028 | 2.255 | 2.399 | 2.688 | 2.376 | 2.520 | 2.695 | EN | 4.424 | 3.973 | 4.105 | 4.870 | 4.507 | 3.533 | 4.499 | 4.531 | SF | 31.89 | 29.57 | 35.06 | 35.28 | 40.17 | 34.79 | 39.78 | 41.20 | | 0.487 | 0.481 | 0.512 | 0.499 | 0.556 | 0.507 | 0.536 | 0.576 | UID | 0.802 | 0.812 | 0.711 | 0.724 | 0.817 | 0.765 | 0.813 | 0.826 |
| ā | Index | DWT | GP | IHS | ST | CT | NSST-4 | NSCT | Proposed |
| Figure 9 | MI | 2.485 | 2.113 | 2.872 | 2.480 | 2.532 | 3.076 | 2.784 | 3.083 | EN | 4.277 | 4.050 | 4.202 | 4.561 | 4.426 | 4.594 | 4.202 | 4.668 | SF | 31.24 | 29.48 | 31.26 | 35.47 | 40.69 | 39.45 | 40.87 | 41.76 | | 0.518 | 0.506 | 0.502 | 0.537 | 0.536 | 0.538 | 0.519 | 0.540 | UID | 0.793 | 0.679 | 0.714 | 0.783 | 0.799 | 0.806 | 0.801 | 0.817 |
|
|